搜尋
網站首頁 關於東生 最新訊息 代理廠牌 聯絡我們
目前位置 : 網站首頁 > 電泳 > 製備級電泳 > NATIVEN 製備級電泳系統
回列表

同類別相關商品

NATIVEN 製備級電泳系統

NATIVEN 製備級電泳系統

商品編號: AT24011
商品名稱: NATIVEN 製備級電泳系統
品牌廠牌: ATTO
商品特點: 針對SDS-PAGE電泳的Protein sample進行分離製備

規格
編號
規格
名稱
價格/
線上詢價
AT2401165 AT2401165
NATIVEN L
詢價單
商品介紹

NATIVEN 製備級電泳系統

產品型號: AE-6760

特點:

  • 高解析度的蛋白質分離與蒐集
  • 氣吹式蒐集系統, 降低sample稀釋與汙染風險
  • 針對大量之sample, 可選用漏斗型管柱
  • 依sample volume 提供 S or L 兩型
  • Concentrate & recover samples without loss
  • easy - to - Use
  • Excellent reproducibility

 

應用: 

  ◇ Fractionation of proteins / DNA using SDS-PAGE 

  ◇ Fractionation of proteins from Native-PAGE keeping with their activites 

  ◇ Concentration of the body fluids (ex. cell-extract, cell culture medium, serum, urine)

  ◇ Purification of antibody epitope 

  ◇ Preparation for Mass Spectrometry 

  ◇ Screening  

 

原理: 

ATIVEN® carries out the preparative electrophoresis by the repeating of 4 processes; separating, pausing, collect-ing and refilling. 

NATIVEN® gel column is made by polyacrylamide disc-gel. It’s separated 3 parts; upper gel, collection part and lower gel. The collection part is filled with the collection buffer. 

The samples is applied to the upper gel and separated by electrophoresis. In the separating phase, the protein bands are eluted into the collection part. Then, the elec-trophoresis paused (pausing phase). Keeping the pause, eluted bands are pushed by air to fraction collector (collecting phase). After the collecting, the collection part is sequentially refilled with a new collection buffer.

 

操作流程: 

 

1. Sample Preparation

  • Samples are available to have been completely solved in sample buffer of PAGE
  • It’s recommended that you pre-purify your samples removing inhibitors of electrophoresis

2. Test PAGE of samples

  • It’s recommended very highly that you check your samples using slab-gel electrophoresis (Test PAGE)
  • The data from Test PAGE are available to set the NATIVEN® program

3. Assembly of NATIVEN®

  • At first, you have to assemble the NATIVEN® gel column
  • Next, you should assemble the NATIVEN® main body, accessories and options

4. Select & Input programs to set experimental condition

  • 4 parameters need to input in the NATIVEN® program
  • These parameters highly affect the outcome of preparative electrophoresis

5. Preparative electrophoresis using NATIVEN®

  • After NATIVEN® running, the preparative electrophoresis processes automatically
  • It’s possible to pause & readjust the program if you have trouble in preparative electrophoresis

 

 

案例說明:

 

A. High resolution protein separation

 

 

 

 

B. Concentrate & recover samples without loss

 

In preparative electrophoresis of NATIVEN®, it’s available to concentrate the focused proteins from the samples of weak concentration.

The left figure shows the concentration of same proteins including bovine serum. 

   bands are more concentrated than the before-separation (bovine serum).

 

 

C. Detection of enzyme activities following SDS-PAGE separation

 

 

SDS-PAGE separation has good resolution of samples, but the isolated proteins activity are lost after that.

 Some proteins, not of all, are possible to recover the activities by SDS removing after SDS-PAGE separation. 

Following data shows the re-covery of enzyme activities following SDS-PAGE separa-tion using lysozyme.

 

 

 

案例統計: 

 

Various size protein or DNA can be separated with SDS/Native electrophoresis by NATIVEN®. 

26 out of 36 experiments are successful in collecting protein samples with their activities conserved.

 

 

規格:

 

 

 

 

 

 

地址:台北市11158士林區福國路21號9樓
北部:電話 02-2831-3061,02-2831-7036 傳真 02-2831-6374 e-mail: bio.east@msa.hinet.net
南部:電話 06-311-4690,傳真 06-311-0360

東生生物科技
藥物傳送-層析裝置-ELISA Kits

網站首頁 關於東生 產品專區 最新訊息 代理廠牌 聯絡我們
買生計產品找東生
已加入詢價單中

訊詢單內容

官方粉絲團 LINE @